Model, run, and analyze with the powerful chart software
What does this software do?
This software allows you to model any building and analyze the heating and cooling energy costs for the building in any climate. Create any building -from a one-room apartment up to a 100+ floor skyscraper-, and account for everything from window coverings to shade trees. Using actual hourly weather data from over 90 climates around the world, this software numerically solves the full thermodynamic differential equations every second of the year, giving you the actual energy usage down to the cent.
Can you step me through a very basic tutorial?
Remember, you can always click on the
icon in the left sidebar to get back to this tutorial.
Click on the
icon in the left sidebar to start a new simulation.
Work your way through the 7 tabs in the main window, and configure all the settings for the simulation you want to run.
Click on the "Run Simulation" button near the top to start the simulation computation.
Once it finishes, you should see the simulation appear as a row in the "Completed" category in the left sidebar. Make sure the row is selected.
View the overall energy costs for the simulation in the main pane. To chart all the recorded data, click on the "View full data chat button" icon in a completed run.
How do I debug the results?
Because simulation models can be very complex, bugs can easily crop up in the simulation. To help debug any problems, try the following tips:
When starting a new simulation, the software will remember all the settings from the last run.
Go to the "Data" tab and select some extra data values to record during the simulation. At the very minimum, select the temperatures of the modules (floors), the power used by the heating and cooling units, and the outside temperature. After you run the simulation, click on the "chart results" button to view all the data items you selected.
First, look at the module temperatures and confirm they are maintaining the temperature comfort limits you selected. Next, look at the heating and cooling power, and confirm the overall energy cost increases when the heating/cooling is using power.
If the module temperatures look strange, try re-running the simulation with even more charting data selected. Look for discrepancies between the outside and inside temperatures, and make sure the heating/cooling systems are attempting to keep the comfort settings you chose.
Run 1: INITIALIZING
When you are ready to run this simulation, click here:
Settings
Weather
Building
Electricity
Energy
Fuel prices
Data
Control
Prices are in US dollars (USD) (need to change the currency or default unit system?)
Price of natural gas
per
Price of LPG gas
per
Price of firewood
per
Price of coal
per
Price of kerosene
per
Price of #2 fuel oil
per
Choose the data save interval (minutes)
Select the data to record for charting afterwards
Choose an overall control type
Choose a control methodology
Select the module to configure below
Lowest acceptable temperature
Highest acceptable temperature
Checkpoint
Time
Lowest temp
Highest temp
Time 1 (weekday)
Time 2 (weekday)
Time 3 (weekday)
Time 4 (weekday)
Time 1 (weekend)
Time 2 (weekend)
Time 3 (weekend)
Time 4 (weekend)
Need to change the default units or time notation?
Select which optimizing programs to use
Humidity optimizer
TBD Intelligent ventilation using forecasts
TBD Lookahead electricity price optimizer
TBD Window-covering optimizer
TBD Room stratification adjustment
Introduction to constraints
It may sound intimidating, but a constraint-based setup is the easiest way to efficiently program your system. For each person in the building, add a constraint for his/her sleep time (with a wider temperature zone) and a constraint for his/her active times (with a smaller zone). You can also set a general constraint for any module to keep the temperature within a certain range when no one is home.
Edit constraint
The constraint name
Which module is this for?
When does this constraint occur?
Choose which day of the week this constraint starts on
Start time
End time
Lowest acceptable temperature
Highest acceptable temperature
Notice: Default values have been changed
Notice: Changes have been made
Simulation Options
2 story house (w crawlspace)
Load default
Load file
Save to file
Edit module parameters
The name for this module
Floor area
Average ceiling height
Thermal mass per floor area
Edit HVAC system parameters
The name for this HVAC system
Choose the system type
Choose the fuel
Which module does the return air come from?
Efficiency of this unit
The SEER of this unit
The HSPF of this unit
The maximum cooling rate for this unit
The maximum heating rate for this unit
The maximum ventilation rate
Edit HVAC link parameters
Choose the HVAC system to use
Is this thermostat for this HVAC system in this module?
Portion of HVAC output directed to this module
Edit portal parameters
Name
Area
Ventilation area
Construction
View/edit construction properties?
How do you want to specify the conductivity?
The R-value
The U-value
The conductivity
The thickness
The absorbtivity
The transmissivity
The specific infiltration rate
The specific heat
The density
Edit barrier parameters
Name
Barrier type
The area of this barrier
The ventilation area
What is on the other side of this barrier?
The compass direction
The inclination angle
The windshield
The sunshield
The sunshield lost in winter
Construction
Show construction properties?
How do you want to specify the conductivity?
The R-value
The U-value
The conductivity
The thickness
The absorbtivity
The specific infiltration rate
The specific heat
The density
Choose a default building type
Choose a heating system type
Choose a cooling system type
Choose a general insulation quality
Enter the overall floor area
Siding or exterior material
Exterior insulation
Sheathing material
Framing type
Interior material
Cavity insulation
SystemSimulatorBuilding heating and cooling energy simulatorCeilingceilingE wallfloorGroundN roofN wallS roofS wallW wallWalls(combined)Cavity materialsFraming materialsInsulation materialsInterior materialsSheathing materialsSiding materialsDemand Billing - bill itemEnergy Charge - bill itemFrom file:AddCreateExport chart dataFallProceedSelectSpringSubmitView full data chartWinterAlbequerque,NMAltoona,PAAmarillo,TXAsheville,NCAtlanta,GABarrow,AKBillings,MTBismarke,NDBoise,IDBoston,MABurlington,VTCalgary,ABCharleston,SCChicago,ILCleveland,OHColumbus,OHDenver,CODetroit,MIEl Paso,TXFairbanks,AKHalifax,NSHonolulu,HIJuneau,AKLas Vegas,NVLexington,KYLos Angeles,CAMemphis,TNMinneapolis,MNMontreal,QBNew Orleans,LANew York City,NYNiagara Falls,NYNorfolk,VANorth Platte,NEOklahoma City,OKOrlando,FLPendleton,ORPhoenix,AZRaleigh,NCRapid City,SDReno,NVSacremento,CASalt Lake City,UTSan Antonio,TXSan Juan,Puerto RicoSault Ste. Marie,MISeattle,WASt Louis,MOToronto,OTVancouver,BCWashington DCWichita,KSWinnipeg,MBYellowknife,NWTAprAugDecFebJanJulJunMarMayNovOctSepTotalTypeBarrierMissingModule (copy)New constraintFriend visitJack is asleepJack is awake (evening)Jack is awake (morning)No one home (1st floor)No one home (2nd floor);Cavity:;Framing:;Ext. insulation:;Interior:;Sheathing:Siding:Choose a control methodologyUse different setup for every moduleUse same control for entire buildingChoose an overall control typeNon-programmable thermostat (fixed)Programmable thermostatUltra-smart control (using TS1 thermostat)(copy)Select the data to record for charting afterwardsChoose the data save interval (minutes)CustomExport data.BasementBuilding New barrierNew doorNo linkNew moduleNew windowSecond floorThird floorThe following links have been broken. This will need to be addressed prior to running simulation.WARNINGCancelConfirmExportOKOkOkayThe file you selected is not a valid building fileContinueLoading a building will delete the current building data.Are you sure you want to delete this?Switching the view will discard your unsaved changes.No simulation selectedSaving will overwrite old template defaults.Duplicating this will discard your unsaved changes.Adding a simulation will discard your unsaved changes.The following links have been broken. This will need to be addressed prior to running simulation.Something went wrong. You appear to be currently offline. The simulator must be online to access new weather data. Either reconnect to the Internet, or use a weather location which you have previously used.Add taskAdd TaskERRORConfirm deleteCopy NameWarningEdit TaskExport data to fileErrorError MessageRun descriptionSaving template parametersDefault valueFieldRun valueNo parameters differ from defaultsS doorTemplate copy nameAdd billing line item.Add a new billing seasonAdd SeasonAdd a new time blockAdd Time BlockAccount Bill Structurebill itemLine item nameEnergy ChargeLine item typeSurchargeFlat ratePeak hoursSeasonal flat rateSeasonal peak hoursSeasonal peak hours advancedBlock start/end timesDemand Billing - Measurment time length (minutes)Price per KW of demandEnergy Charge - Billing typeCost per KWHOther seasonsSummerTimeNo data availableKWH priceNo non base ratesYear round KWH base rateReactive Billing - End month / dayEnd date must be after start date.Date range overlaps with exsisting seasonSeason nameStart month / dayerr: end before starterr: Overlapping another seasonSurcharge amountTotal monthly surchargesEnd hour / minuteKWH price is not a numberStart time must be before end time.Start hour / minuteerr: KWH price is not a numbererr: end time before start timeYear round peak ratesNo tasks have been addedAdd Energy UnitBattery Custom loadSolar panelsLoad Solar BatteryGenerationLoadsStorageLoad TypeRunning a simulation requires at least one moduelThe gap between hightest temperature and lowest temperature must be at least one positive degree FahrenheitIf the climate city you chose is far away from your location, optionally correct the latitude to your locationIf the climate city you chose is far away from your location, optionally correct the longitude to your locationChoose a name for this simulationIf the timezone for your location differs from the climate city you selected, change it hereFor now, the only batch mode is to run a comparison with 10 other weather locations around the worldEnter a detailed description or comments. This field is only for reference, so enter any detailed info here that explains the simulation parameters.Select the last day of the simulation. The year is not included since the simulator uses average yearly historical weather data.If the climate city you chose is far away from your location, optionally correct the latitude to your locationIf the climate city you chose is far away from your location, optionally correct the longitude to your locationFor most buildings, the electricity is billed at a constant price. However, more utilities are offering per-hour pricing to help reduce the electricity demand during peak times.Our TS1 thermostat is available in the US and Canada, however we still include a small sample of world citiesNormally you will only be running 1 simulation at a time. However, you can also queue up a batch of simulations to perform, and have the application step through many different scenarios all at once.Select the first day of the simulation. The year is not included since the simulator uses average yearly historical weather data.The starting air temperature establishes the starting point for the numerical solverChoose a name for this templateIf the timezone for your location differs from the climate city you selected, change it hereType of SweepAmplitudeCharging start timeControl TypeCurrent ChargeMinimum Useable ChargeDurationEquationMaximum ChargeBattery NameCharging RateTasksTemplateUsage start timeBattery VoltageChoose a location which best represents your climateDescriptionPrice of electricityEnd DateOptionally correct the latitude for your exact location (+ is N)Load NameScheduleOptionally correct the longitude for your exact location (+ is E)Price of natural gas (per 1000 ft³)Choose the electricity pricing type: Choose a region of the world 1Choose a region of the worldSimulation TypeSolar Panel NameExpected Energy OutputSolar Panel TypeStart DateStarting TemperatureAdmin / SurchargeEnd TimeStart TimeTemplate NameCorrect the UTC timezone offset for your exact location (hours)Price of coal (per ton)Price of firewood (per cord)Price of kerosene (per gal)Price of LPG gas (per gal)Price of natural gas (per 1000 sq ft.)Price of #2 fuel oil (per gal)Highest acceptable temperature10:00 (10AM)22:00 (10PM)02:00 (2AM)14:00 (2PM)04:00 (4AM)16:00 (4PM)06:00 (6AM)18:00 (6PM)08:00 (8AM)20:00 (8PM)00:00 (midnight)12:00 (noon)HVAC EfficiencyCoalElectricity#2 fuel oilKeroseneNatural gasPropaneWoodFuel typeHSPFMax cooling rateMax heating rateMax ventilation rateair conditionerboilerelectric heaterfurnaceheat pumpswamp coolerwood stoveHVAC air return moduleSEERArea heater (fireplace, etc)AbsorbtivityBarrier areaCompass directionConstructionDensityInclination angleInfiltration rateBarrier nameWhat is on the other side of this barrier?Show construction properties?Specific heatSunshieldSunshield lost in winterThicknessBarrier typeVentilation areaWindshieldHVAC nameHVAC typeIs the thermostat for this HVAC system in this module?Portion of HVAC output directed to this moduleHVAC system to useAverage ceiling heightFloor areaModule nameThermal mass per floor areaOutput formatAreaPortal typeNameTransmissivityTime formatLowest acceptable temperature3 1/2" blown cellulose5 1/2" blown cellulose (attic)7 1/2" blown cellulose (attic)5 1/2" blown fiberglass (attic)5 1/2" fiberglass batt (floor)7 1/2" blown fiberglass (attic)7 1/2" fiberglass batt (floor)3 1/2" fiberglass batt3 1/2" extruded polystyreneR-40 combo (attic)R-60 combo (attic)3 1/2" rock wool batt3 1/2" urea terpolymer foamMetal insulating (2" with urethane)Solid core flush (1 3/4")Solid core flush (2 1/4")Wood hollow core flush (1 3/4")2x4 soft wood lumber2x6 soft wood lumber2x8 soft wood lumber8" concrete block4" poured concrete25/32" fiberboard1" fiberglass1" foil-faced polyisocyanurate1" extruded polystyrene3/8" paneling1/2" plywood3/4" plywood3/8" plywood1/2" drywall5/8" drywall1/2" fiberboard1x4,1x6 soft wood lumber5/8" particle boardasphalt shingles (dark color)sphalt shingles (light color)wood bevel lappedBrickcarpet (fibrous pad)1/2" hardboardhardwood floor (oak)none5/8" plywoodrubber floor padtile, linoleum (floor)vinly siding with 1/2" insulation boardvinyl,aluminum,or steel sidingwood shingles (cedar)double pane 1/2" air spacedouble pane with 2 suspended filmsdouble pane 1/2" with Low-Esingle glasssingle glass with stormtriple pane 1/2" air spaceAtticCrawlspaceFirst floorSlabRun NameShow difference tableConductivityEarth (ground)Neighbor's roomOutside airR-valueNoYesFloorWallU-valueCompare with 10 world citiesCompare all available controlsLook at simple home upgradesLook at substantial home upgradesAutomatedManualStepComma separated (CSV)BoilerFurnacenoyesFlatLocal time zone timestampAdvanced ConfigFlat-rateHourly (varies during the day).US and CanadaRest of the worldRelative seconds from first data pointRun a set of simulationsRun one simulation at a timeAdvanced Solar PanelsDefault Solar PanelsTab separated (TSV)UTC seconds since 1970Excel (XLSX)Door typeLoad constructionWindow typeDemand BillingCoolingHeatingSourceSurcharges hour minute% done second left)Save TemplateSubmitEnergy ProfileThis simulation is currently running, and is paused (click step to continue)This simulation is waiting for another run to finish before starting. (floor BuildingControlDataEnergyFuelResultsSettingsWeather OptionsSimulation RunExporting data...Loading...Saving the run...Saving the simulation...Saving template...air temperatureCooling ratedew pointenergy costenergy usageground temperatureHeating rateEnergy costinternal temperatureOverallrelative humiditysky coversnow depthsolar fluxthermal mass temperaturewind directionwind speedbarriersBuildingsTemplate 1HVAC linksHVAC systemsModulesRunsSimulationsAdd simulation1000 foot³liter1000 ft³LthermR-factor (SI)R-factor (US)U-factor (SI)U-factor (US)cordThe gap between hightest temperature and lowest temperature must be at least one positive degree FahrenheitE windowN windowS windowW windowAir conditionerUse heat pump defined aboveSwamp coolerWith basementChoose a cooling system typeWith crawlspaceEnter the overall floor areaNumber of FloorsChoose a heating system typeChoose a general insulation qualityChoose a locationSimulation NameBoiler (natural gas)Boiler (propane)Electric heatFurnace (natural gas)Furnace (propane)Heat pumpNoneWood stoveWell-insulatedLowMediumLoadNew1 Story House2 Story House3 Story HouseManufacturing FacilityOffice FacilityWarehouseCommercialImport templatesNew SimulationResidentialTemplates